Used Convection Ovens: Vulcan VC4GD vs Blodgett Zephaire, and the Robertshaw Recall

What the CPSC recall notice and the Vulcan and Blodgett documents say about two used gas convection ovens, and the price, repair and lifespan figures we removed.

Updated: 2026-10-26

Two gas single-deck convection ovens come up again and again in used listings: the Vulcan VC4GD and the Blodgett ZEPHAIRE-100-G. Vulcan's spec sheet lists the VC4G series with "One 50,000 BTU/hr. burner." and a "two speed 1/2 H.P. oven blower-motor". Blodgett's model page lists the Zephaire as "Natural Gas, 50000 Total BTU". On paper they are the same size of oven. They are not the same purchase, because of a 2006 recall that names both brands.

Check the ID plate before the price

In August 2006 Robertshaw Controls recalled gas controls installed in commercial cooking equipment. The Consumer Product Safety Commission notice gives the hazard plainly: "The recalled controls can remain on after the pilot light is extinguished." There are two separate parts on two separate brand lists.

  • FS Flame Switches. "The recalled FS Flame Switches were installed on the following commercial cooking equipment brands: Keating (of Chicago), PMI Food Equipment Group, Vulcan, Southbend, Blodgett, Toastmaster, and Wolf Range."
  • FM Automatic Safety Valves. "The recalled FM Automatic Safety Valves were installed on the following commercial cooking equipment brands: Bari (Restaurant and Pizzeria), Southbend, and Blodgett."

So Vulcan appears on the first list only. Blodgett appears on both, which means a Zephaire from the affected period has two controls to rule out, not one. The notice puts the sale windows at "from August 2005 through June 2006 for the FS Flame Switches and from April 2006 through June 2006 for FM Automatic Valves".

The notice does not list ovens by model. It says "The model and/or serial numbers can be found on the cooking appliance identification plate located on the appliance." and "For a list of appliances with recalled switches and valves, visit www.robertshaw.com." An earlier version of this page said there was no list to check against. That was wrong. We have not retrieved the Robertshaw list, so check it yourself with the plate in hand. The remedy is stated as: "Consumers who believe they could have recalled safety valves on their cooking appliances should contact Robertshaw Controls Co. who will arrange for a free replacement, if necessary." A unit from the affected period with no record of a control replacement should not be bought until someone has checked.

What the manufacturers document about heat and ignition

On the Vulcan, the installation and operation manual lists the causes of a burner that is not on. They run through relay, transformer, switch and board faults: "If burner is not on: 1. Relay failure. 2. 24V transformer failure. 3. Motor/Centrifugal switch failure. 4. Temperature control board failure. 5. Ignition board failure." That list includes a motor switch, so a fan-side fault can present as a heat fault. A buyer who hears "it won't heat" should ask which of these was actually diagnosed.

For the ignition itself the same manual gives a separate list: "1. Problem with gas supply/gas valve. 2. Ignitor failure/Improper spark gap. 3. Flame sensor failure. 4. Ignition board failure 5. Temperature control board failure. 6. High limit is open." The Vulcan service manual adds a measurable test: "Micro Amp reading from the flame sensor should measure a minimum of 0.7 Micro Amps to maintain burner ignition." A technician can take that reading. Ask for it.

We could not retrieve an official Blodgett troubleshooting document for the Zephaire. Blodgett's model page says only "ZEPHAIRE-100-G -BASE is a base section (oven only) intended to replace an existing ZEPHAIRE-100-G." So we say nothing here about how Zephaires fail.

What we removed

We removed all prices: the new list and street figures, the used comps (several of which turned out to be double-stack ovens), the Blodgett new prices and the freight line. We removed the repair-video blower story, the forum-sourced ignition fault lists, the parts availability grades, the service intervals and the expected-life figure. None is stated in a manufacturer or CPSC document, and we will not print what we cannot trace.

Before you buy either one

  • Read the ID plate and check the model and serial against the Robertshaw list.
  • Ask for the ignition service record and for the flame sense reading on a Vulcan.
  • Light the oven and run the blower on both speeds. Walk away if it will not start cleanly.
  • Get a dealer quote for the specific part you suspect before you negotiate. We have no part prices to give you.

Sources